SDM-300A Satellite Modem Revision 6
Front Panel Operation MN/SDM300A.IOM
5–43
FUNCTION SELECT: CONFIGURATION: LOCAL AUPC:
NOMINAL POWER (CONDITIONAL)
NOMINAL POWER
-10.0 dBm
IMPORTANT
Conditional: This menu is displayed when Local Modem AUPC = ON
located under the Utility: Modem Type menu.
Programs AUPC Nominal Power Value Range: -5 to -30 dBm, in 0.5 dBm steps
Upon entry, the current nominal power value is displayed. Press [] or [] to increase or
decrease the digit at the flashing cursor. Press [ENTER] to execute the change.
FUNCTION SELECT: CONFIGURATION: LOCAL AUPC:
MINIMUM POWER (CONDITIONAL)
MINIMUM POWER
-30.0 dBm
IMPORTANT
Conditional: This menu is displayed when Local Modem AUPC = ON
located under the Utility: Modem Type menu.
Programs the AUPC Minimum Power Level Range: -5 to –30 dBm, in 0.5 dBm steps.
Programs the minimum power level of the AUPC. Upon entry, the current minimum power
value is displayed. Press [] or [] to increase or decrease the digit at the flashing cursor. Press
[ENTER] to execute the change.