G.6.4.1.3.5 Set Modulator Output Power Level
Command: <add/MOP_snn.n”cr”
Response: >add/MOP_snn.n”cr””lf”]
Status Only: <add/MOP_”cr”
Response: >add/MOP_snn.n”cr””lf”]
Where:
For the 140 MHz modulator, snn.n = +20.0 to -45.0, in 0.5 dB increments.
For the 70 MHz modulator, snn.n = +20.0 to -30.0, in 0.5 dB increments.
Notes:
1. Power levels may be programmed for a maximum value specified by the
modulator power, offset with a range of 25 and 10 dB below the maximum value
for the 140 MHz modulator and the 70 MHz modulator, respectively.
2. See the “MPO_” command specification for more information.
G.6.4.1.3.6 Scrambler Enable
Command: <add/SE_xxx”cr”
Response: >add/SE_xxx”cr””lf”]
Status Only: <add/SE_”cr”
Response: >add/SE_xxx”cr””lf”]
Where: xxx = ON or OFF.
G.6.4.1.3.7 Differential Encoder Enable
Command: <add/DENC_xxx”cr”
Response: >add/DENC_xxx”cr”lf”]
Status Only: <add/DENC_”cr”
Response: >add/DENC_xxx”cr”lf”]
Where: xxx = ON or OFF.