SDM-300L3 Satellite Modem Revision 0
Remote Control Operation MN/SDM300L3.IOM
A–41
Character 'r': Interface Reed-Solomon Unavailable
Seconds
Bit 6 = 1 always.
Bit 5 = not used.
Bit 4 = not used.
Bit 3 through Bit 0 = Binary representation (0 to 10) of
the number of Reed-Solomon Unavailable Seconds
stored faults.
Character 's': Outdoor Unit Status Character 1.
Bit 6 = 1 always.
Bit 5 = Current.
Bit 4 = Voltage.
Bit 3 through Bit 0 = Binary representation (0 to 10) of
the number of Outdoor Unit stored faults.
Character 't': Outdoor Unit Status Character 2.
Bit 6 = 1 always.
Bit 5 = reserved.
Bit 4 = reserved.
Bit 3 = reserved.
Bit 2 = reserved.
Bit 1 = reserved.
Bit 0 = reserved.
Change
Status
Command:
Response:
<add/CS_'cr'
>add/CS_x'cr''lf']
Where:
The 'x' character is defined as follows:
'@' = no change since last BCS_ and BCSF_ polls.
'A' = BCS_ response has changed since last BCS_ poll.
'B' = BCSF_ response has changed since last BCSF_
poll.
'C' = Both responses have changed since last BCS_
and BCSF_ polls.
This command indicates that a change has or has not
occurred on either the BCS_ or the BCSF_ response since
the last BCS_ or BCSF_ poll.
Equipment
Type
Command:
Response:
<add/ET_'cr'
>add/ET_tttttttt_xxx.yyy.zzz'cr''lf']
Where:
tttttttt = Equipment type.
xxx.yyy.zzz = Software version.
Monitor &
Control
Firmware
Information
Command:
Response:
<add/MCFI_'cr'
>add/MCFI_'cr'
VER_xxx.yyy.zzz'cr'
FW/nnnnnn-ddr'cr'
mm/dd/yy'cr''lf']
Where:
xxx.yyy.zzz = Software version number (0.0.0 to
999.999.999).
nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).
DATA ROM
Firmware
Information
Command:
Response:
<add/DFI_'cr'
>add/DFI_'cr'
FW/nnnnnn-ddr'cr'
mm/dd/yy’cr’
Turbo: FW/nnnnnn-r'cr''lf']
Where:
nnnnnn = Firmware number (0 to 999999).
dd = Firmware dash number (0 to 99).
r = Firmware revision (-, or A to Z).
Note: If Dash number is not used, '-dd' will be reported.
Turbo FW number only reports if Turbo Codec is
installed.
Vedere la pagina 408
1 2 ... 404 405 406 407 408 409 410 411 412 413 414 ... 433 434

Commenti su questo manuale

Nessun commento

Tripp Lite APSINT612 manuály

Uživatelské manuály a uživatelské příručky pro Nabíječky autobaterií Tripp Lite APSINT612.
Poskytujeme 1 manuály pdf Tripp Lite APSINT612 ke stažení zdarma podle typů dokumentů: Uživatelský manuál






Další produkty a příručky pro Nabíječky autobaterií Tripp Lite

Modely Typ Dokumentu
PowerVerter RV1012UL Uživatelský manuál   Tripp Lite PowerVerter RV1012UL User's Manual, 2 stránky
HCRK-INT Uživatelský manuál   Tripp Lite HCRK-INT User's Manual, 16 stránky
UT Series Uživatelský manuál   Tripp Lite UT Series User's Manual, 12 stránky
HCRK-3 Uživatelský manuál   Tripp Lite HCRK-3 User's Manual, 12 stránky