CDM-600 Satellite Modem Revision 7
ODU Operation MN/CDM600.IOM
D–5
D.2.6 (ODU,ENABLE,1:1,CSAT#1) CONFIGURATION
(ODU,ENABLE,1:1,CSAT#2) CONFIGURATION
(ODU,ENABLE,STANDALONE CSAT) CONFIGURATION
CONFIG: TX-PARAMETERS RX-PARAMETERS
LNA-PARAMETERS MISCELLANEOUS
Use the [] or [] keys to select the parameters to configure, then press ENTER.
D.2.7 (ODU,ENABLE,1:1,CSAT#1,CONFIG) TX
(ODU,ENABLE,1:1,CSAT#2,CONFIG) TX
(ODU,ENABLE,STANDALONE CSAT,CONFIG) TX
TX: FREQ=6427.0 MHz ATT=23.00 dB
AMP=OFF MUTE=UNMUTED SLOPE
Use the [] or [] keys to select the parameter to edit. Use the [] or [] keys to edit
the parameter, then press ENTER to implement, or CLEAR.
The user may edit the TX Frequency, the TX Attenuation, the Amplifier setting or the
Mute setting. The Slope parameters are edited in another menu, so use the [] or []
keys to select Slope and press ENTER.
D.2.8 (ODU,ENABLE,1:1,CSAT#1,CONFIG,TX) SLOPE
(ODU,ENABLE,1:1,CSAT#2,CONFIG,TX) SLOPE
(ODU,ENABLE,STANDALONE CSAT,CONFIG,TX) SLOPE
TX SLOPE: MODE=MANUAL (MANUAL,CAL)
SLOPE=0.3 (0.0 - 1.0)
Use the [] or [] keys to select the parameter to edit. Use the [] or [] keys to edit
the parameter, then press ENTER to implement, or CLEAR.
The Slope Mode may be either CALIBRATED or MANUAL. If MANUAL is selected,
the Slope may be edited.