MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–10
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Command or
Response to
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
(Instruction
Code and
Query
(Target to
Configuration
Status
48 bytes (BDC),
41 bytes (BUC),
alphanumeric
Returns the summarized version of RCS.
Example for MBT-04000 base unit:
<0001/CCS?{cr}
>0001/CCS=aa,bb,cc,dd,e,ff,g,h{cr}{lf}
Where:
aa=Frequency band for Unit 1 BXC (‘C”, ‘X”, ‘Ka’, ‘Ku’, or ‘NA’)
bb=NA
cc=Direction for Unit 1 BXC (‘DN’=BDC, ‘UP’=BUC, ‘NA’=None)
dd=NA
e=Redundancy mode (0, 1, or 2)
ff=Automatic mode
g=Redundancy loop cable address
N=No Cable
A=MBT-A
B=MBT-B
h=External reference lock (1=locked, 0=Not locked)
Example BUC/BDC:
<0001A1/CCS?{cr}{lf}
>0001A1/CCS=aaaaa,bb.bb,c,d.d,e,ff,g,hhhh,i,j,{CR}{lf}
Where:
aaaaa=Frequency in MHz
bb.bb=Attenuation in dB
c=mute state, 0=unmated, 1=muted
d.d=slope adjust
e=LNA current source (BDC only, BUC=X)
ff=LNA current window (BDC only, BUC=XX)
g=LNA fault logic (BDC only, BUC=X)
hhhh=XXXX (reserved for future use)
i=X (reserved for future use)
j=Fault recovery, 0=Manual, 1=Auto
(see Description of
Arguments for
details)
Current
BDC
Sets the calibration point for the LNA/LNB current alarm feature in the form
s, where:
s (Source)=1 (LNA A (AUX COMM)) or 2 (LNB Bias Tee)
Example: CLC=2 would record the current measured for the LNB bias tee
CLC?
CLC*
CLC!