MBT-4000B Multi-band Transceiver System Revision 1
Serial-based Remote Product Management MN/MBT4000B.IOM
6–13
Parameter
Type
Command
(Instruction Code
and qualifier)
Valid on
MBT or
BUC/BDC
Command or
Response to
Description of Arguments
(Note that all arguments are ASCII numeric codes – i.e., ASCII codes
between 48 and 57)
Response to Command
(Target to Controller)
(Instruction
Code and
Query
(Target to
Frequency
BUC
numeric
Sets or returns valid Operating RF frequency, in MHz.
For Ku BDCs:
FRE values: 10950-11700 MHz an LO of 10000 MHz is activated
FRE values: 11701-12250 MHz an LO of 10700 MHz is activated
FRE values: 12251-12750 MHz an LO of 11300 MHz is activated
FRE?
FRE*
FRE!
(see Description of
Arguments for
details)
Firmware
Number
Returns the Firmware Number of the unit.
Example: FRW=FW12357’cr’’lf’
Current
BDC
Returns the LNA/LNB Current Source Level in mA in the form s_xxx.x,
where:
s=1 (LNA A) or 2 (Bias Tee)
xxx.x= LNA Current Source Level in mA
Example:
<0001/LCM?2
>0001/LCM=2_045.3{cr}{lf}
LCM?
LCM!
Source
BDC
Sets or returns LNA Current Source Enable in the form sx, where:
s=1 (LNA A AUX COMM) or 2 (LNB Bias Tee)
x=0 (Disable) or 1 (Enable)
Example: LCS=20 (turns off the LNB Bias Tee current)
LCS?)
LCS*
LCS!
(same format as
command
arguments)
Window
BDC
numeric
This command allows the user to set the alarm window in ± % of the
calibrated LNA/LNB Bias Current in the form sxx, where:
s=1 (LNA A AUX COMM) or 2 (LNB Bias Tee)
xx=Valid inputs are 20 to 50 in increments of 1%. Setting the value to 99
disables the alarm function.
Default is Disabled.
Example: LCW=230 sets alarm window for LNB Bias Tee to ± 30%.
LCW?
LCW*
LCW!
(same format as
command
arguments)
Commenti su questo manuale