Vedere la pagina 87
SDM-2020 Satellite Demodulator Revision 4
Front Panel Operation MN/SDM2020D.IOM
6–24
Function Select: Monitor: Corrected BER
CORRECTED BER
4.0 E-3
Displays the current corrected BER estimated or No Data (if carrier is not locked).
Range: <m.m E-e to >m.m E-e.
Notes:
1. Low limit based on modulation and coding selection.
2. High limit is 1.0 E-12.
Press [] or [] to move the flashing cursor, and [] or [] to increment or decrement
the selected kbps. Press <ENTER> to execute the change.
Function Select: Monitor: Eb/No
EB/NO
16.0 dB
Displays the current E
b
/N
0
estimated or No Data (if carrier is not locked).
Range: <mm.m to >mm.m.
Notes:
1. Low limit based on modulation and coding selection.
2. High limit is 16.0 dB.
Press [] or [] to move the flashing cursor, and [] or [] to increment or decrement
the selected kbps. Press <ENTER> to execute the change.