SDM-2020 Satellite Demodulator Revision 4
Front Panel Operation MN/SDM2020D.IOM
6–28
2047 ERRORS
NO DATA
Receives 2047 BER. This is a monitor point that displays the current RX2047 BER. If no
data is available, “NO DATA” is displayed.
Notes:
1. SAMPLING is displayed when gathering data. This process can take several
minutes to calculate a BER based on a 2047 test pattern.
2. Available only with G.703 interface installed.
Press [←] or [→] and [↑] or [↓] to increment or decrement the selected kbps. to move
the flashing cursor. Press <ENTER> to execute the change.