CRS-300 1:10 Redundancy Switch Revision 16
Remote Control MN/CRS300.IOM
C–14
Parameter Type
Command
(Code and
qualifier)
Arguments for
Command or
Response to
Query
Description of Arguments
(Note that all arguments are ASCII numerical codes,
that is, ASCII codes between 48 and 57)
Response to Command
(Target-to-Controller)
Query
(Code and
qualifier)
Response to query
(Target-to-Controller)
TMI/RMI types N/A 11 Bytes Query only.
Where x indicates theTMI type detected in each slot
position:
0 = none present
1 = CRS-320 Rev A
2 = CRS-330
3 = CRS-340 Rev A
4 = CRS-340 Rev B
5 = CRS-370 (HSSI)
6 = CRS-320 Rev C
7 = Undefined
8 = CRS-341
9 = CRS-316
A = CRS-336
B = Undefined
C =CRS-315 (TMI)
D = CRS-325 (TMI)
E =CRS-335 (TMI)
F = CRS-345
G= CRS-365 Quad E1 for CDM-Qx
H= CRS Quad E1 D-sub for CDM-625
y indicates the RMI detected in slot II
0 = none present
7=CRS-310
D=CRS-307
E=CRS-306
F=CRS-305
Example: XMI=21000000007
N/A XMI? XMI=xxxxxxxxxxy
(see Description of
Arguments)
Vedere la pagina 263