Comtech-ef-data RCS20 Manuale Utente Pagina 64

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
Vedere la pagina 63
RCS20 M:N Redundancy Switch Revision 15
User Interfaces MN-RCS20 and CD-RCS20
4–30
Key Label Function
S3 --- N/A
S4 RETURN Press to return to the AUTO MODE BACKUP ASSIGNMENT SUMMARY Screen.
Numeric Keypad ---
Used to enter the prime channel number to switch to Backup Channel 2.
Press <CLR> or <NEXT> to abort programming (no switch parameters changed).
Press <ENT> to load the information on the screen into the switch parameter table.
Switching will occur immediately after pressing <ENT>.
4.3.2 CONFIG SYSTEM Menu Tree
4.3.2.1 CONTROL MODE CONFIGURATION
This screen allows the user to modify the control mode. The Control Mode may be one of the following:
FT PANEL - Front Panel Control - Commands will only be accepted from the front panel and
keypad.
TERM - Remote Terminal Control - Commands will only be accepted through the RS-232
terminal connection.
COMPUTER - Command Interface Control - Commands will only be accepted from the RS-484
remote port connection.
4.3.2.1.1 Programming steps:
1. Press <FT PANEL>, <TERM>, or <COMPUTER> to select the desired control mode. The mode
will be selected immediately after pressing the appropriate key.
Key Label Function
S1 FT PANEL Press to select Front Panel Control.
S2 TERM Press to select Remote Terminal Control.
S3 COMPUTER Press to select Command Interface Control.
S4 NEXT Press to cycle to the next screen.
CONTROL MODE CONFIGURATION
CONTROL MODE: FRONT PANEL
<FT PANEL> <TERM> <COMPUTER> NEXT