RCS20 M:N Redundancy Switch Revision 15
User Interfaces MN-RCS20 and CD-RCS20
4–51
4.3.2.26 RDM FALLBACK CONFIGURATION
This screen allows the user to configure the RDM Internal Reference Frequency. The internal frequencies
may be one of the following:
• MHz
• MHz
• MHz
• 10.0 MHz
4.3.2.26.1 Programming steps:
1. Press <TOG MODE> to change the displayed internal frequency.
2. Continue pressing <TOG MODE> until the desired frequency is displayed.
3. Press <CLR> or <RETURN> to abort programming (no switch parameters changed).
4. Press <ENT> to load the information on the screen into the switch parameter table.
Key Label Function
S1
TOG
MODE
Press to cycle through the above listed internal frequencies.
S2 --- N/A
S3 --- N/A
S4 RETURN
Press to cycle back to the REFERENCE DISTRIBUTION CONFIGURATION
Screen.
Numeric Keypad ---
Press <CLR> or <RETURN> to abort programming (no switch parameters
changed).
Press <ENT> to load the information on the screen into the switch parameter table.
RDM INTERNAL REFERENCE CONFIGURATION
INTERNAL FREQ : 10.0 MHZ
TOG MODE RETURN